If installed correctly by a reputable company like Foam Tech, spray foam creates a thermal envelope around your structure. The building stays more comfortable and less susceptible to outside weather, and the HVAC has an easier job with the maintenance of indoor temperature. As the experts on spray foam insulation for Lubbock and Dallas, TX, we can answer any questions you may have. Call us today at 214.205.1200 to learn more or schedule service.
In the early days of insulating attics, people believed the insulation was a heat source. That’s not the case, as the insulation is actually a barrier between two areas of different temperatures. As for the “hot roof” theory, the unvented attic system could make the temperature of the roof go up a little, but this increase won’t cause damage to your shingles.
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US.  https://m.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
Roof coatings made with acrylics, urethanes or asphalt soften under the stress of ponding water or snowpack. Eventually, these roof coatings will bubble and peel away from the substrate, leaving your roof vulnerable to leaks, rot, and decay. However, GacoRoof’s 100% silicone formulation is designed to stand up to whatever the elements dish out. Silicone will withstand areas of ponding water without softening, bubbling or peeling from the substrate. Acrylic, urethane and asphalt roof coatings decompose and wear away from the stress of harsh sunlight, UV rays, and freeze-thaw cycles.

how to buy spray foam insulation


Polyurethane Spray Foam Insulation is used in industries ranging from mining to movies, from cold storage to marine flotation. Spray Foam Insulation’s ability to seal out air and insulate quickly means it’s always in high demand for residential and commercial applications. Spray Foam Insulation is critical for solving our nation’s energy challenges because it dramatically reduces the energy needed to heat and cool our homes and offices.

spray foam garage ceiling


In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

where to buy polyurethane spray foam


Polyurethane is a closed-cell foam insulation material that initially contains a low-conductivity gas in its cells.[5] As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch.[5] In comparison, blown fiberglass typically has an R-Value of only R-3 to R-4 per inch.[6]

I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.
The United States has adapted to using sprayfoam insulation and a new technology called Wall Injection to retrofit existing wall construction by drilling small holes between wall studs in the structures framing and filling the void with a less aggressive expanding water based foam. This allows existing home and business owners to conserve energy by creating a thermal envelope in their existing structure.

Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.).
Barrier’s specially-trained technicians have applied over 5 million square feet of coatings in a wide variety of commercial, industrial and residential settings throughout the United States. With our experience, product knowledge and long list of satisfied customers, Barrier is uniquely qualified to give your enterprise the protection it deserves.  

spray foam existing wall


Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.). http://m.www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

Never spray foam on a surface with a moisture level of more than 20 percent—the foam won’t stick. If the surface you’re spraying hasn’t been exposed to water for a few weeks, it should be OK to spray. But if you’re patching a wall that recently sustained water damage, or was just assembled with new, wet lumber, you may want to test the moisture level before you spray. You can get a moisture meter here.


Spray foam insulation, when properly installed is both an air barrier and when closed cell foam is used at the proper depth a vapor barrier!  Before hiring any contractor you should establish the brand of foam being used and verify that with the named manufacture.  Please ask for ESR reports and MSDS sheets on any foam being installed in your home. A couple areas where you might consider spray foam insulation include:
If installed correctly by a reputable company like Foam Tech, spray foam creates a thermal envelope around your structure. The building stays more comfortable and less susceptible to outside weather, and the HVAC has an easier job with the maintenance of indoor temperature. As the experts on spray foam insulation for Lubbock and Dallas, TX, we can answer any questions you may have. Call us today at 214.205.1200 to learn more or schedule service. https://www.youtube.com/watch?feature=youtube.be&v=ggLAUsiuI_o
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level.

If you cut the nails holding one of the corner studs to the bottom plate and the top plate with a Sawzall, you can use a flat bar (or a flat bar plus a wrecking bar) to pull the stud off the sheathing nails. Either re-use the stud, or buy a new stud, and install the stud with toenails as shown in the link I provided in Comment #51 (this link: Outside corner detail).
Johns Manville has partnered with No-Burn, Inc. to offer No-Burn Plus ThB. This tintable white, thin film intumescent coating can be applied over JM open- and closed-cell polyurethane foams. When exposed to high temperatures and flame it intumesces, which creates a char-barrier to reduce heat transfer and surface burning in the event of a fire. This nontoxic, water-based coating complies with IRC and IBC and can serve in lieu of otherwise code-prescribed thermal barriers. 
Henry 687 100% Acrylic Enviro-White Extreme Elastomeric Roof Henry 687 100% Acrylic Enviro-White Extreme Elastomeric Roof Coating is a premium high solids white reflective roof coating. It features Dirt Pick-Up Resistance (DPR) technology which prevents dirt and dust buildup keeping the roof whiter and more reflective longer. When cured it forms a permeable membrane which prevents liquid infiltration ...  More + Product Details Close
I recently did a remodel project for my basement using spray foam insulation. The original builder has used fiberglass, but I wanted the best insulation i could find. We chose closed cell foam because it blocks moisture from getting into the house. It took one day to install and was fumey for about 3 hours. It was pretty cool watching it being done. It comes out as a liquid and then expands rapidly into a foam. It's quick! Then they took a types of saw to shave it flat with the wall studs so we could then go ahead and drywall.

where to spray foam in attic


We had issues with getting this foam to turn green in summertime in the South. We needed up spending an additional $300 on being able to spray this foam: 110 window a/c for shop & a $60 tarp to drape over the top, to keep the temps down. The areas where we had trouble-shooted were sticky & even after we wiped it down, the new green foam wouldn't stick. My husband had to apply Liquid Nails to it. For over $800, I expected alot more, plus the sellers customer service skills were in need of improvement.
Typical roof coating dry film thickness vary from paint film thickness (plus or minus 3 dry mils) to more than 40 dry mils. This means a roof coating actually becomes the top layer of a composite roof membrane and underlying system. As such, the roof coating is the topmost layer of protection for the membrane, receiving the impact of sunlight (both infrared and ultraviolet (UV), rain, hail and physical damage.
For 2×4 stud walls, the fiberglass insulation will have to be split to fit. In this case, we sprayed just under 2 in. of foam (R-10.8), and split 3-1/2-in. R-13 batts in half (R-6.5) to achieve an R-17.3 insulation value. Never cram oversize batts into a wall cavity because fiberglass insulation loses R-value when it’s compressed. You could save money by spraying 1 in. of foam and adding more fiberglass, but don’t spray less than 1 in.—the foam will no longer serve as an air barrier. This particular foam creates its own vapor barrier if sprayed 2 in. thick.

how much spray foam in attic


Unlike fiberglass, cellulose or other loose fill products, our Foamsulate products can be applied with precision almost anywhere, expanding to completely fill gaps and spaces with a long-lasting solid. No matter how irregular the shape, how rough the surface or how hidden the area, Foamsulate products create an exact fit and an effective, high-quality air barrier that lasts. Foamsulate™ can be used wherever air can get in:
I used this for the rim-joist in our home. A couple things: I put 1in solid core foam (cut to size) in each bay before using the spray foam. I also was able to do a relatively 'thick' spray to close off any potential gaps that may have existed. I turned off the HVAC and turned on some fans in the windows to exhaust out the fumes, and wore a mask (3m respirator).

Also, I'm wondering... Is this website is being regularly updated? A local installer (in Oct, 2010) in MA quoted over twice the price you list here. "Open cell alone ~$1.35 per sq ft for R-13. Or a 'hybrid method' using 2inch closed cell for R-13 followed by 1.5inch open cell for R-6. Hybrid is $2.85 per sq foot for R-19 rating". Maybe installers are charging higher prices to profit from those trying to meet government energy rebate by Dec 31?

how much is spray foam insulation cost


This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the "Accept All Cookies" button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy   Accept All Cookies

spray foam crawl space


I never heard of Oak Glen before, but do recognize the mountain names. I wouldn't expect to find any towering Sequoias and Redwoods there because neither species is native to that part of California, and they do take some time to become towering. And I've never heard of any overlapping of their ranges. A more suitable house for this location might get inspiration from the Monolithic Dome in Yucaipa which survived a direct hit from a wildfire.
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.
Carefully examine the roof membrane (surface material) for cracks, tears, blisters, evidence of ponding, exposed foam, and open seams. If already coated, evaluate the condition of the coating. Pay particular attention to areas around roof penetrations (vents, skylights, pipes, etc), ponding areas, cracks in parapet walls, and the attachment of roof membranes to parapet walls. Roofs should be in good condition to warrant coating.
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.).
I've seen this only once, and it was with closed cell foam, but I've heard of it happening with open cell foam, too. I don't know the details, but I've heard it could result from a bad batch of chemicals, improper mixing, or too high a temperature. Whatever the cause, it's not a good thing. The photo below shows how the spray foam pulled away from the studs. A little bit of uninsulated area like that adds up to a lot of heat loss/gain when the whole house has that problem, as it did here. https://youtube.com/embed/ggLAUsiuI_o
×