Spray foam is available in two different types: open-cell spray foam which is usually $0.44 to $0.65 per board foot and closed-cell spray foam which is about $1 to $1.50 per board foot. The average cost to have spray foam professionally installed is about $2,314. This number can vary depending on whether the home being insulated is newly constructed. However, finished homes are not a good candidate for spray foam insulation but great for weatherization or an energy audit.  
Silicone coatings are typically produced by adding a catalyst and solvents to a silicone base. Because the silicone is a natural material, these coatings are bio-degradable. They can be applied to a roofing system using many different techniques, including spraying or rolling. Silicone coatings are available in many colors, including reflective white and translucent.
Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors.
United Coatings™ Roof Coat Elastomeric Coating is an effective coating for providing long-term reflectivity over a wide range of roofing substrates. The high reflectivity of Roof Coat Elastomeric Coating keeps the roof substrate cool, which not only helps prolong its longevity but also helps save on energy costs. Roof Coat Elastomeric Coating’s rich consistency uniformly covers the textured profile of various substrates, forming a flexible monolithic membrane that provides protection from normal weathering, aging, and ultraviolet exposure.
Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating Sta-Kool 780 Siliconized Acrylic White Elastomeric Roof Coating is a high quality flexible white acrylic roof coating. Product is enhanced with silicone for improved water resistance adhesion and life expectancy. Product resists cracking peeling while offering tremendous durability and long term life. The coating forms a durable protective barrier which ...  More + Product Details Close

The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials.

EPDM coatings has been featured in Article Insider, as well as Roofers Exchange, Building Service Management and recently won Metal Roofing Magazines product of the year. Since it’s the only liquid form of EPDM rubber in the world, made right here in the U.S.A. there are many distinct advantages to the product vs other roof coatings. It waterproof as soon as it is applied, will take standing water indefinitely yes that means 365 days a year of continued ponding water. The product comes with a pre-measured bottle of catalyst that is added to the container. Once the material is mixed you have a 4 hour time period to apply it before it starts the initial set up process. The product requires daytime temperatures of at least 55° to cure. Temperatures can fall below 55° at and once they rise again above the 55 degree mark it will continue to cure. Any non-opened can be stored up to one year without it going bad. Roof leak repairs are an unwelcome reality to every owner of a residential or commercial building, mobile home or recreational vehicle. Roof leak repairs can include almost anything including replacing damaged shingles, mending holes, fixing roof leaks, or repairing dents with roof coatings.

Spray Foam Professionals


Get the Power to Seal & Insulate Perfectly in Just 5 Minutes. The Foam it Green Promise: 1>Simpler, Easier, Faster Spray Foam 2>No Special Skills or Know How 3>Professional Results or Better Saves You Time, Money and Hassles. Delivers to your door, ready to use. Just follow the simple instructions. Saves Energy with High R-value Closed Cell Foam. R-Value of 7 in Just 1 Inch. Provides a seamless air barrier in 1 step. This Kit Provides Approx. 602 Square Feet at 1” thickness of cured foam. Class I E-84 Fire-Retardant Foam that meets building code specs. This Anti-Microbial Formula passed the stringent ASTM G-21 test for preventing mold growth on the surface of the foam. Includes everything you need to complete your project. Weighs 120 lbs, including steel canisters pressured with nitrogen. Orders with multiple kits on it may ship via LTL instead of UPS. The LTL carrier calls to arrange a convenient delivery time. Usually Ships Same Business Day. See Manufacturer for returns and warranty policy.

Spray Foam Trailer Rental


c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.

This website uses cookies and other tracking technologies (also known as pixels or beacons) to aid your experience (such as viewing videos), as well as “performance cookies” to analyze your use of this website and to assist with marketing efforts. If you click the “Accept All Cookies” button or continue navigating the website, you agree to having those first and third-party cookies set on your device. If you do not wish to accept cookies from this website, you can choose to not allow cookies from this website by updating your browser preferences. For more information on how we use Cookies, please read our Privacy Policy. https://www.youtube.com/v/ggLAUsiuI_o&feature=youtube_gdata
Henry 287 Solar-Flex White Roof Coating is a Henry 287 Solar-Flex White Roof Coating is a premium elastomeric water-based acrylic latex coating designed to reflect the sun's heat and UV rays. Properly applied it is highly resistant to disbonding chalking mildew and discoloration. Expands and contracts with your roof to protect it from leaks aging mold mildew and ...  More + Product Details Close
Touch ‘n Foam Pro System 600 is a completely self-contained 2-component foam system that is portable and disposable. Complete with color-coded hoses, ergonomic foam applicator, and all the necessary tools to get started, the System 600 provides up to 600 board feet* (theoretical) of polyurethane spray foam. Designed for larger insulating (up to 2 inch fills), sealing, patching and filling applications, the System 600 provides a quick, consistent flow of foam with rapid curing (60 seconds) to insulate stud wall cavities, gaps, cracks, expansion joints, and other sources of air leakage.

Spray Foam Garage Ceiling


I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US. 
Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.

The guys who sprayed my attic were trained and certified, but I later found out, too late, that they had no experience and my attic was the first they'd ever sprayed. I was also never told to vacate my house for any length of time, and so I (and my pets) were in the house the day they sprayed and the entire time the off ratio foam was filling my home with horrendous vapors. The company kept telling me that it was a good job and I had nothing to worry about, even after I'd had 2 other experienced sprayers from 2 different companies visually examine the foam and confirm that large areas appeared to be off ratio. The 3rd sprayer from yet another company, was also outraged because the company who did my attic had failed to vacuum up all of the old cellulose insulation, and he also noticed areas where the foam was shrinking or pulling away, and this was not even 5 weeks after the spraying.  


I don't even want to ask this question but... several years ago we hired a local contractor to spray high density foam on the roof deck and walls of our unfinished 2nd floor. We realized that the job was done poorly and cut an access into the attic space to assess things. We realize now that they spray foamed directly to the chimney (no flashing). The chimney is currently used for a woodstove and DHW venting. The DHW will go away but wood stove will remain. My question is, how bad (unsafe) is this? I have found information on foam exposure to fire but have not been able to find anything about temperature ratings in general (i.e. what happens on prolonged exposure to high temperatures).
The process by which heat energy in the form of light (usually IR unless the substrate is hot enough to glow in the visible range) is emitted more strongly by warm surfaces and absorbed by other materials especially those of low IR reflectivity (think matte black finish). Radiant heat transfer does not require a medium. Foam insulation materials, such as spray foam insulation, are opaque to thermal radiation, like most solid materials.

The roof must be thoroughly cleaned, and allowed to dry thoroughly. This is a critical step to ensure a successful coating application. Be careful not to damage the lap seams. Care should be taken when pressure washing not to disturb the integrity of the underlying roof membrane particularly where there are adhered seams. Refer to the specific coating manufacturer you are using for their specific requirements for roof preparation.


United Coatings™ Roof Coat Elastomeric Coating is an effective coating for providing long-term reflectivity over a wide range of roofing substrates. The high reflectivity of Roof Coat Elastomeric Coating keeps the roof substrate cool, which not only helps prolong its longevity but also helps save on energy costs. Roof Coat Elastomeric Coating’s rich consistency uniformly covers the textured profile of various substrates, forming a flexible monolithic membrane that provides protection from normal weathering, aging, and ultraviolet exposure. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=%2Fwatch%3Fv%3DXXXXXX%26feature%3Dshare
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) http://www.youtube.com/e/ggLAUsiuI_o
Please Note: Prices, promotions, styles and availability may vary by store and online. Inventory is sold and received continuously throughout the day; therefore, the quantity shown may not be available when you get to the store. This inventory may include a store display unit. Online orders and products purchased in-store qualify for rebate redemption. Mail-in Rebate is in the form of merchandise credit check, valid in-store only. Merchandise credit check is not valid towards purchases made on MENARDS.COM®. By submitting this rebate form, you agree to resolve any disputes related to rebate redemption by binding arbitration and you waive any right to file or participate in a class action. Terms and conditions available at www.rebateinternational.com®
If you’re looking for an effective and efficient Elastomeric Roof Coating, you might want to consider the Kool Seal roof coating. This product comes in a 115 fl oz container and is white in color. It is easy to apply and use that it can stick well even in the harshest weather conditions. This product offers maximum clinging to the RV roof despite the temperature. You can also rely on its effectiveness no matter the type of weather. https://www.youtube.com/v/ggLAUsiuI_o
During colder months, 2 component foam is very sensitive to temperature variances. Per product instructions, both tank temperatures need to be above 70°F (21°C) for at least 24 hours prior to use. All application surfaces should be clean/dry and above 60°F (16°C) prior to application. Variance outside of the recommended temperature can affect foam yield and performance.
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]
The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit.  http://m.youtube.com/embed/ggLAUsiuI_o
Solvent-based polyurethane coatings have excellent adhesion and when used as a base coat over asphalt, EPDM, TPO or PVC, it eliminates the need for a primer. The resulting savings on labor and material more than offsets the higher cost of the product. When top coated with silicone, it gives you the best of both worlds. It's also an excellent gutter and RV coating. https://m.youtube.com/v/ggLAUsiuI_o
When looking for a long-term roof solution, compare apples to apples. Liquid EPDM Rubber is a one-coat application. There are no primers needed, and when you begin adding up the cost of other systems that require primers and multiple coats, you are often exceeding the cost of liquid EPDM Rubber and have an inferior sealant on your roof. Why add unnecessary weight to a roof by using multiple-coat systems? Cut your time and labor costs in half with a one-coat system. Liquid EPDM has a very thick honey-like consistency and a slow cure time. One of the biggest benefits of the product. During the cure process, you will see bubbles resembling those created when you cook a pancake. This is the catalyst at work forcing the trapped air to the surface. What you have after the cure is a chemical bond between your roof and the coating. No other coatings produces this result. Other products trap this air making future cracks inevitable as temperatures change or expansion and contraction of the roof occur.
The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit. 

How Much Is Spray Foam Insulation Per Square Foot

×