Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
Roof Coatings should not be confused with deck coatings. Deck coatings are traffic bearing - designed for waterproofing areas where pedestrian (and in some cases vehicular) traffic is expected. Roof coatings will only waterproof the substrates but will not withstand any kind of on going use by people or vehicles (such as walkways, patios, sundecks, restaurants, etc.). http://m.www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

There should be a foam sill sealer between the bottom plate and the concrete foundation wall. But voids in the wood or concrete, or tears in the sill sealer, can create gaps where air and insects can penetrate. While you’re sealing the rim board, cover the bottom plate and top off the concrete as well. There’s no need to picture-frame the joist spaces before filling them, but don’t spray a lift more than 2 in. thick.
Repair and seal roof penetrations, tears, open seams, etc. using Elastek 103 Crack & Joint Sealant and reinforce with polyester roof fabric as necessary. In larger or deep ponding areas, apply Elastek 500 Puddle Plaster to fill in areas that hold water. Avoid using plastic roof cement. Serious ponding should be referred to a roofing contractor. Blisters in previous coatings may be opened but these areas must be allowed to dry-out completely. Blisters in the roofing ply should be left alone unless likely to break. Caulk and reinforce open seams, roof penetrations, cracks, and tears. These are potential leak points so work carefully and thoroughly. Use fabric to build flashings around roof edges or roof penetrations, and to reinforce various coating repairs. A polyester fabric is used because it will stretch with the coatings. (Fiberglas fabric is not recommended.) Fabric is normally cut to extend three inches beyond the repaired area in all directions. The coating is applied to the roof surface and the fabric is immediately pushed into the wet surface. An additional coat is applied over the fabric and the patch is allowed to dry. If your roof has stucco parapets, examine them for cracks along the sides and top. These areas often permit water to enter the wall and can cause blisters and wrinkles in the roof surface. Repair with Elastek 103 Crack & Joint Sealant. If you do not have parapets, examine the metal drip edge for a tight seal with the roof membrane. Use 4″ or 6″ roofing fabric covered under and over with Crack & Joint Sealant to seal cracks along drip edges, penetrations, and open seams.
Allison--would be very interested in your take on the GHG issues of foams, which have received lots of smart commentary recently. To highlight a few: architect Jesse Thompson's comments on Tom's Good vs Bad post on Energy Circle, the very thorough piece by Alex Wilson on Green Building Advisor and Michael Anschel's cautionary diatribe on Remodeling. 
Prices, promotions, styles, and availability may vary. Our local stores do not honor online pricing. Prices and availability of products and services are subject to change without notice. Errors will be corrected where discovered, and Lowe's reserves the right to revoke any stated offer and to correct any errors, inaccuracies or omissions including after an order has been submitted.
That’s $58.3 Billion dollars. That’s roughly how much money we wasted in 2010 in the US according to the Department of Energy because of air leaking out of our building envelopes. If your building leaks energy, you’re paying more for energy than you need to. Clearly you’re not alone. If you’re ready to claim your share of the savings, it’s quicker and easier than you think.
The insulation at eaves level will leave your loft area comfortable for use and free from condensation. By installing the insulation at rafter level, it keeps the loft void warmer and prevents condensation build-up, which can otherwise occur when increasing insulation at ceiling level. The warmer, drier, cleaner roof space eliminates the risk of pipes and tanks freezing.
Spray foam comes in two flavors, open cell and closed cell, and provides both parts of the building envelope - the insulation and the air barrier. The building envelope should completely surround the conditioned space, and the insulation needs to be in contact with the air barrier. Since spray foam is both insulation and air barrier, proper alignment of insulation and air barrier is guaranteed.
If you're chemically sensitive, it's probably not a good idea to get it installed, but it's also not a good idea to breathe musty air from the crawl space either. In addition, your house and its contents are made of lots of materials that affect your indoor air quality. If you're really concerned about this, hire a company to test your air and tell you what you can do about it.
Roof coatings are easy to install. Smaller roofs in good, serviceable condition can be a weekend do-it-yourself (DIY) project. Larger roofs with leaks and ponding water issues should be coated by a qualified professional. Additional roof coating products, such as foam or coatings designed for seams, may be required underneath the main coating layers. Supplement coating products are used to reinforce damaged or leak-prone problem areas.[3] https://m.youtu.be/ggLAUsiuI_o
×