2. I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. I would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing.

This depends on the geographic location, insulation, and cost of electricity. Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL), National Roofing Contractors Association (NRCA), and several roofing material manufacturers have computer programs that can estimate the savings. A growing number of energy consultants are available to provide environmental regulation compliance information.
This tropic heat actually is the cause that the steel structure, which most roofs in that part of the world are built on, expands and contracts all the time. By doing so, the sun-battered steel structure causes the roof tiles to dislodge and slowly creates small openings between the roof tiles, through which rain water can run into, creating leaks that can cause much damage to plastered ceilings and electric wiring. https://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.” http://youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
EPDM coatings has been featured in Article Insider, as well as Roofers Exchange, Building Service Management and recently won Metal Roofing Magazines product of the year. Since it’s the only liquid form of EPDM rubber in the world, made right here in the U.S.A. there are many distinct advantages to the product vs other roof coatings. It waterproof as soon as it is applied, will take standing water indefinitely yes that means 365 days a year of continued ponding water. The product comes with a pre-measured bottle of catalyst that is added to the container. Once the material is mixed you have a 4 hour time period to apply it before it starts the initial set up process. The product requires daytime temperatures of at least 55° to cure. Temperatures can fall below 55° at and once they rise again above the 55 degree mark it will continue to cure. Any non-opened can be stored up to one year without it going bad. Roof leak repairs are an unwelcome reality to every owner of a residential or commercial building, mobile home or recreational vehicle. Roof leak repairs can include almost anything including replacing damaged shingles, mending holes, fixing roof leaks, or repairing dents with roof coatings.

Spray Foam Professionals


Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 

Spray Foam Walls


Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct?
Although spray polyurethane foam has many advantages over other types of insulation, spray foam installation isn’t foolproof. Some builders have reported problems with sloppy foam insulation. For example, some installers have been known to begin spraying before the chemical components are up to temperature, which can affect component mixing and foam performance. When components are poorly mixed, or mixed in the wrong ratio or at the wrong temperature, cured foam has been known to shrink away from rafters or studs, leaving cracks. Some installers rush through their spraying, resulting in voids. http://www.youtube.com/watch?feature=youtu.be&v=ggLAUsiuI_o
RetroFoam of Michigan has more than 15 years of experience insulating thousands of homes and pole barns across the lower peninsula. We hear a lot of misconceptions about foam insulation and work to make sure we clear up any wrong ideas about foam insulation. Our staff helped us put together this list of misconceptions adding their insights to dispel any misinformation.
Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close

Spray Foam Metal Building


Roof coatings are easy to install. Smaller roofs in good, serviceable condition can be a weekend do-it-yourself (DIY) project. Larger roofs with leaks and ponding water issues should be coated by a qualified professional. Additional roof coating products, such as foam or coatings designed for seams, may be required underneath the main coating layers. Supplement coating products are used to reinforce damaged or leak-prone problem areas.[3]
Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
For maximum durability and leak resistance, we recommend that two coats of topcoat be applied at 100 sq. ft. per gallon, or a minimum of 20 mils dry coating. If two complete topcoats are not applied, always apply two thick coats to problem areas such as scuppers, drain areas, ponding areas, seams, and repaired areas. Avoid using Elastek Solar Magic™ or The Shield™ on ponding roofs. Clean skin and tools promptly with water.
As mentioned above elastomeric coatings can be used to fix almost all types of roofs. Examples of common roof types that will work well with elastomeric coatings include; wood, polyurethane foam, single-ply roofing, modified bitumen, metal roofs, concrete and built-up roofing. If you aren't sure your roof type will work well elastomeric coatings, do not hesitate to contact us. Our experts are always willing to help. https://youtube.com/v/ggLAUsiuI_o
Prices, promotions, styles, and availability may vary. Our local stores do not honor online pricing. Prices and availability of products and services are subject to change without notice. Errors will be corrected where discovered, and Lowe's reserves the right to revoke any stated offer and to correct any errors, inaccuracies or omissions including after an order has been submitted.

Amanda previously has worked as a breaking news and crime reporter, TV news producer, and editor in Flint and Detroit. Throughout her career as a journalist, she has won several awards from the Detroit Chapter of Society of Professional Journalists and the Michigan Press Association. As part of the RetroFoam of Michigan family, Amanda uses her experience as a journalist to write content that will help educate homeowners on the benefits of foam insulation. When Amanda isn’t writing, she’s spending time with her husband and rescued huskies. She also loves knitting, making art, cooking, and hosting dinner and a movie night for friends and family.


I have used the Froth-Pak 200 to air-seal rim joists--the area above the foundation wall in a basement. The first time I used it I did not shake the canisters well enough and the foam did not cure properly. Don't just shake the box for a few seconds. I take the tanks out of the box so I can shake/invert each tank for a minute or two. You will be able to hear the chemical sloshing around in the tanks. Also, don't ignore the recommended temperature for application--around 75 degrees F.

I'm in the process of redoing my basement and read through the posts. I took out one inch styrofoam covered by 1/4 " beadboard and installed 2X4s and plan on putting in fiberglass batts between them(r-13) with 1/2 in drywall over top of that. Do you think I will see a significat increase in heat control? Should I have done more?... it's a little after the fact, but still curious to know if I will see a big difference based on your experience. https://www.youtube.com/watch?v=ggLAUsiuI_o&feature=youtu.be

Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors. 

United Coatings™ Roof Coat Elastomeric Coating is an effective coating for providing long-term reflectivity over a wide range of roofing substrates. The high reflectivity of Roof Coat Elastomeric Coating keeps the roof substrate cool, which not only helps prolong its longevity but also helps save on energy costs. Roof Coat Elastomeric Coating’s rich consistency uniformly covers the textured profile of various substrates, forming a flexible monolithic membrane that provides protection from normal weathering, aging, and ultraviolet exposure. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=%2Fwatch%3Fv%3DXXXXXX%26feature%3Dshare
If your foam pulled away just a little bit, Jamie, and they were able to fix it with just a little bit of touching up, then it wasn't as bad as the house where I saw this problem. As the last photo above shows, it had pulled away significantly from the studs and rafters, and it was all over the house. This was closed cell foam, and interestingly, it didn't pull away from the horizontal framing members, just the vertical and sloped ones. They did some touch up, but that wasn't enough. I don't know how this one ended up getting resolved. I think maybe the contractor came back and sprayed cellulose on top of the foam.

How Much Is Spray Foam Per Sq Ft

×