Thank you, Allison. We have a split system unit (actually 5) with the heat being propane. The foam guy said that it needed ventilation, so completely sealing the attic wouldn't be a good idea. It sounds like you are saying that the systems need to be vented out of the attic or replaced with some type of closed system. But I shouldn't bother spraying if the plan is to leave the soffet vents open. Is that correct?

how much is spray foam roofing


Thanks for asking for our input. I have enjoyed the 'Future House' episodes that you folks have created. And, I think that the amount of segments-per-season seems just about right - any more and it might begin to take the shows into an area that moves away from their core meaning (i.e. - home repair/rehab/construction, etc). Though, it's easy to understand how new and upcoming technologies fit well into TOH/ATOH's overall picture. Also, Ross Trethewey is a good sement host - very knoledgable and enthusiastic - and, as well, he gives the TOH/ATOH audience some 'younger blood' to continue forward with the show's traditions. My thoughts are to stick with 'Future House' segments.And, thanks for all of the good work you folks do in continuing to present to us each year such wonderful productions as TOH and ATOH, which we get to enjoy and benefit so greatly from!


My project was a 2 part one.  First the guest house was to be used for an elderly couple with some health issues.  The idea of using chemicals which can be harmful to the respiratory track has made me change my mind about proceeding. The guest house was single story with a low attic height and 600 square feet and the main house (part 2)  is 2,800 sq feet. After reading the comments below, I would like a quote from someone that uses a soy product that is non toxic. .  
Spray foam is a fully adhered insulation that is spray applied into wall cavities, providing a continuous air and moisture barrier. Spray foam allows efficient use of your HVAC system and helps regulate the temperature fluctuations and humidity in your home. Spray foam effectively seals the building envelope, filling in any cracks and crevices, the common source of air and moisture infiltration as well as temperature variations.
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.
Current guidelines recommend up to 10 inches of insulation in your attic . This is usually added to the ground, rather than the roof line, which results in the loss of your storage area, due to not being able to refit floor boards after installation. By implementing spray foam insulation to the roof line, you regain the lost 10 inches, thus increasing storage, height and practicality.

where to use spray foam


I am an Architect in Toronto. I am designing a new roof addition to a row house building. Because of existing conditions and the shape of the new roof. It may be easiest to use closed cell spray foam within the areas of the joists. My question is when spray foam is used in this situation do I need to worry about how the joist members may be thermal bridges? It is not common to provide a little bit of rigid insulation to protect the joist members? The additional layer of outboard insulation will require an extra layer of plywood above the insulation which will add to cost.

Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces.  http://youtube.com/embed/ggLAUsiuI_o


Never spray foam on a surface with a moisture level of more than 20 percent—the foam won’t stick. If the surface you’re spraying hasn’t been exposed to water for a few weeks, it should be OK to spray. But if you’re patching a wall that recently sustained water damage, or was just assembled with new, wet lumber, you may want to test the moisture level before you spray. You can get a moisture meter here.

how much is open cell spray foam insulation


Sporadic cases of hypersensitivity pneumonitis (HP) have also been reported in workers exposed to isocyanates. The symptoms may seem like the flu, with fever, muscle aches, and headaches. Other symptoms may include a dry cough, chest tightness, and difficult breathing. Individuals with chronic HP often experience progressively more difficult breathing, fatigue, and weight loss. Individuals with acute HP typically develop symptoms 4–6 hours after exposure.[4]

The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.)

how much for spray foam insulation in attic


Tucson Rubberized Coatings is on the cutting edge of technological advancement in the coating industry. From driveways to walls and rooftops, our products have you covered. Established in 1992, we have decades of research that has not only led us to create the best products of today, but is also providing the foresight in the formulation of the products for tomorrow.

spray foam attic ceiling


We live in middle TN and had our house foamed last year. We noticed recently that some of the foam was shrinking and seperating from the floor joists. We contacted the installer and he informed us that the manufacturer had a problem with a batch of foam during the time frame we had our house sprayed. The contractor wasn't sure if we had the recalled batch installed in our house or not. He said he would check the batch numbers and let us know. He seems like a nice guy promising to do whatever it takes to fix any problems. Do we trust him, however, to be truthful about the batch number? Do we have any options for finding out the information ourselves? I inspected the entire crawl space of the house and noticed approximately (5) areas that were seperating and a couple areas where the foam didn't adhere to the block. Do I assume by it being so infrequent that it is nothing to be concerned about? My concern is the walls that are not capable of being visually inspected because of sheetrock.

Amanda previously has worked as a breaking news and crime reporter, TV news producer, and editor in Flint and Detroit. Throughout her career as a journalist, she has won several awards from the Detroit Chapter of Society of Professional Journalists and the Michigan Press Association. As part of the RetroFoam of Michigan family, Amanda uses her experience as a journalist to write content that will help educate homeowners on the benefits of foam insulation. When Amanda isn’t writing, she’s spending time with her husband and rescued huskies. She also loves knitting, making art, cooking, and hosting dinner and a movie night for friends and family.

A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.


We had issues with getting this foam to turn green in summertime in the South. We needed up spending an additional $300 on being able to spray this foam: 110 window a/c for shop & a $60 tarp to drape over the top, to keep the temps down. The areas where we had trouble-shooted were sticky & even after we wiped it down, the new green foam wouldn't stick. My husband had to apply Liquid Nails to it. For over $800, I expected alot more, plus the sellers customer service skills were in need of improvement.
Wall spray foam has a dynamic effect on your walls. Every nook and cranny becomes filled, which prevents against lost air or the entry of air from outside. These energy savings from wall spray foam can become immense: up to 50 percent off your energy bill when coupled with foam in the attic. Wall spray foam also presents a waterproof barrier to the outside. Since it does not absorb moisture like traditional insulation, it protects your siding and walls from deterioration.

Good article, but it seems like you can chalk up almost all of those problems to the experience level of whomever is spraying the foam. Spray foam isn't an inherently bad product, but it's pretty easy to botch if the hired company is inexperienced. Fiberglass may be foolproof to install, but then again it has a terrible R-Value compared to a good spray foam. People just need to get referrals and do their homework whenever they research a spray foam contractor.
Sealection 500 is a spray-applied adhesive, which once applied, expands in place using water-blown technology, without CFCs, HCFCs, or ozone-depleting chemicals. Unlike traditional fiberglass insulation, Sealection 500 will maintain its performance; time and temperature have no effect on the spray foam insulation's R-value of 3.81 at 1 inch. Sealection 500 never deteriorates or decomposes. The product retains its shape and half-pound density over time, and never settles or compacts. http://youtube.com/v/ggLAUsiuI_o
×