The local foam installer that I used here in Hilton Head told me he looked for some peeling back of the foam. This was ensuring that it was at the perfect temperature which helped them maximize their yield (profit). I have open cell foam and it pulled away a little, and did so immediately (within minutes). They went back after they were done to any spots that pulled away too much and filled them with the touch up kit; they were looking for the top edge to roll just a little bit.  https://youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
This is more common with closed cell foam, but it happens with open cell foam, too. Since closed cell foam has a higher R-value per inch, installers generally spray 2" in walls and 3" in rooflines to meet the energy code requirements of R-13 and R-19, respectively. (I'm not going to dive into the energy code here, but these numbers apply to many climate zones, the latter being allowed under the UA tradeoffs rule. See the Energy Nerd's blog on this topic if you want to argue.) http://youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Most closed-cell spray foam is now formed using hydrofluorocarbon (HFC) blowing agents that have high global warming potential, partially or completely offsetting the climate benefits of the energy savings they can offer. In the United States, HFCs are scheduled to be phased out by January, 2021. A few spray foam suppliers have started supplying spray foam blown with hydrofluoroolefin (HFO) blowing agents without this problem as of early 2017.[14]

how much does it cost for spray foam insulation


To avoid the expense re-roofing a house that is simply suffering from nail fatigue, and to obtain optimum insulation, an 85mm layer of polyurethane foam can be sprayed onto the underside of the slates or tiles of a pitched roof. This stabilises and weatherproofs the roof by fixing the nails, battens and roofing felt. As the foam is a superior insulant, coupled with just 100mm of insulation at joist level, your roof will also meet the stringent thermal performance standards required for a new home. A typical roof can be insulated using the polyurethane treatment for around half the cost of re-roofing. https://www.youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o
There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.

2. I talked to a building product supplier for WALLTITE spray foam, he is suggesting to use 2" or 3" of closed cell spray foam in the joists areas instead of the batts insulation. He says it will work with outboard rigid insulation. There is a location of a cantilevered floor area with steel beam so I may need to use spray foam to protect the steel beam. I would then be convenient continue to spray in the floor joist cavities and then apply 5" of polyiso outboard of the bottom cantilever floor sheathing.

spray foam house


With constant exposure to heat, cold, UV radiation, rain, snow, hail, high winds and possible mechanical damage, a roof can be the most vulnerable component of a building’s exterior. However, a roof’s long-term performance can be enhanced — and major roofing problems avoided — with correct design, quality materials, proper installation and workmanship, and comprehensive care.
While the R value will vary, most ocSPF products have an R value of around 3.8 per inch. Unlike medium-density closed-cell SPF, ocSPF is not a vapour barrier. When installed at 5.5 inches or more, ocSPF does act as an air barrier. It is often used for interior walls because it provides sound reduction by blocking and absorbing air leakage. It is usually only recommended for indoor applications.
Heatlok®, is a high-performance, versatile spray foam insulation designed for residential construction. Its unique formula incorporates recycled plastic bottles and renewable oils to create high-performance, closed-cell spray foam insulation. This polyurethane insulation combines multiple control layers into a single application, saving homeowners both time and money in construction costs. With our innovative technology, Heatlok is developed with 14 % renewable and recycled content, and is the ideal choice for residential construction. http://www.youtube.com/watch?feature=youtube_gdata&v=ggLAUsiuI_o
Product innovation over the years has seen the introduction of several different types of spray foam insulation. Primarily in residential and commercial construction, open-cell and closed-cell spray foam is used while high-density spray insulation is used as roofing foam in commercial or industrial construction. Open-cell sprayed-in foam insulation, a soft low-density material, is typically used for interior applications such as wall cavities, underside of roof decks, attics, basement walls and crawlspaces. The open cell structure of low density foamed insulation allows for moisture permeability to help contribute to moisture management and bi-directional drying of the wall assembly.
Roof coatings are easy to install. Smaller roofs in good, serviceable condition can be a weekend do-it-yourself (DIY) project. Larger roofs with leaks and ponding water issues should be coated by a qualified professional. Additional roof coating products, such as foam or coatings designed for seams, may be required underneath the main coating layers. Supplement coating products are used to reinforce damaged or leak-prone problem areas.[3] http://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be
I started using Gaco years ago primarily to solve ponding water Problem. It has work well, solved my problems with other roofing options and repairs as well as many other Flat roof issues.  My only problems were experienced when I did not clean the surface well enough for good adhesion.  Follow the Instructions.  Great product and highly recommended. .
Sealection 500 is a spray-applied adhesive, which once applied, expands in place using water-blown technology, without CFCs, HCFCs, or ozone-depleting chemicals. Unlike traditional fiberglass insulation, Sealection 500 will maintain its performance; time and temperature have no effect on the spray foam insulation's R-value of 3.81 at 1 inch. Sealection 500 never deteriorates or decomposes. The product retains its shape and half-pound density over time, and never settles or compacts.
What do you mean by "our AC units require fresh air ventilation"? Fresh air doesn't come from the attic. If there's an atmospheric combustion appliance in the attic, such as an 80 AFUE furnace, then you shouldn't be encapsulating the attic anyway. If that's the case, you don't want spray foam on the roofline at all. You can either change out the furnace to a sealed combustion unit or do your insulating and air-sealing at the flat-ceiling level.
Silicone based coatings can be spray or roller-applied, and should utilize a medium-nap roller when rolled. These coatings are applied anywhere from 2 to 3.5 gallons per 100 square feet, depending on the substrate. Silicone has two major advantages over the other four types of coatings that should be considered when searching for the best roof coating: 1) it can resist ponding water for extended periods of time and 2) it can adhere to most substrates without a primer. Because of these two major advantages, silicone is the best roof coating that satisfies both quality and cost-effectiveness.
Some states, municipalities and utilities have programs. Check with your coatings manufacturer for further information. As a membership benefit, RCMA provides maintains a database of current information on rebates and tax credits for installing reflective roofs. RCMA’s customized search tool can be used to find the most up-to-date listings of reflective roofing financial incentives available.
Our roof coating sprayers are designed to provide the coverage, flow rate, and pressure needed for all your applications. Durable Graco roof coating sprayers are equipped with valuable features that make them extremely versatile. High-quality parts plus gas, electric, air driven, and hydraulic options means we’ll have a sprayer that fits your needs. Our systems are designed to be used with elastomeric roof coatings, silicone roof coatings, acrylic roof coatings, asphalts, rubber roof coatings, and other materials.

spray foam professionals


Spray foam insulation is typically priced by volume, meaning your cost will depend on how much material you need to use to insulate your space, although other factors may influence price as well. In most cases, the cost of spray foam insulation is more than worth it, as it's a once and done upgrade that will not only provide energy savings in your home, but also improve your home's overall comfort.

The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) https://m.youtube.com/embed/ggLAUsiuI_o

If installed correctly by a reputable company like Foam Tech, spray foam creates a thermal envelope around your structure. The building stays more comfortable and less susceptible to outside weather, and the HVAC has an easier job with the maintenance of indoor temperature. As the experts on spray foam insulation for Lubbock and Dallas, TX, we can answer any questions you may have. Call us today at 214.205.1200 to learn more or schedule service. https://www.youtube.com/watch?feature=youtube.be&v=ggLAUsiuI_o

There are several types of reflective roof coatings that impart varied reflectance rates/ values. Typically, the reflective coatings are what are commonly referred to as white coatings and there are also aluminum coatings typically used with asphalt. Highly reflective white roof coatings are typically comprised of acrylics, urethanes, silicones, SBS, SEBS, and other types.
Johns Manville Corbond III® closed-cell spray polyurethane foam insulation offers and R-Value of R-7 per inch and can be applied in a single pass to a maximum of 3.5 inches, providing superior thermal performance with seamless air sealing and moisture control in a single step. Multiple immediate passes, with no wait time, may also be applied. With high yield and excellent adhesion, it's an ideal choice for high-performing energy efficient commercial, residential and industrial applications. https://youtube.com/watch?v=ggLAUsiuI_o
×