RE: my June 12 post...We went ahead and had the attic sprayed with a Soy-based product. Stayed in a hotel for 3 nites. Still smelled a little bad but that's gone away over time. I'm very glad we didn't use the other foam as even that much outgassing of a petrochemical could have sent my wife to the hospital. Unfortunately, the spray crew didn't speak English(at least not to me) and were kinda lazy, so they ended up spraying over some can fixtures from the kitchen below that were not insulation-contact rated. So I hired an electrician to come out, pull down the cans, pull out what he thought was an appropriate amount of foam to create a big enough air space and then re-install the cans. I billed the firm for the electrician plus an extra night we had to stay in the hotel and they paid, no questions asked. Guess they knew they had screwed up.  
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
I employed a company to insulate my three story house in 2011. They started Insulating it in August of 2011...They said it would be a 3-4 day job. They installed it in 0.5"-8" lifts all in the same cavity, this left burned insulation and voids. They removed what they told me was the bad insulation and in the process cut many electrical wires. They fixed this. They then reinstalled too thick again in some spots and removed again. They then installed it for a 3rd time. The areas that I thought were good are now separating from the structural members leaving voids. As of October 2012, 1 year and 2 months of dealing with the contractor I told them I want proof that what has been installed carries a warranty or I want my money back and I will fix the problems myself. They have yet to provide me with this warranty. I have spent many hours in the house looking at what is bad and they need to fix. I am frustrated, 14 months of additional rent due to their negligence. I would like to know how I can get proof that the product carries the manufacturers lifetime warranty, or has it been installed improperly throughout the entire house. Desperately awaiting your response. 
Today’s “third generation” of blowing agents have a GWP of 700 to 1000 which is still remarkably high considering water/CO2 has a GWP of 1. However, innovation from some chemical manufacturers like the Chemours Company have introduced the next generation of HFO blowing agents such as Opteon 1100, which significantly reduces the GWP impact when using closed-cell spray foam insulation products.
If you cut the nails holding one of the corner studs to the bottom plate and the top plate with a Sawzall, you can use a flat bar (or a flat bar plus a wrecking bar) to pull the stud off the sheathing nails. Either re-use the stud, or buy a new stud, and install the stud with toenails as shown in the link I provided in Comment #51 (this link: Outside corner detail). https://m.youtube.com/embed/ggLAUsiuI_o
Spray foam insulation, like other insulation, saves on energy costs and lowers utility bills. Studies by the US Department of Energy show that 40% of a home's energy is lost as the result of air infiltration through walls, windows and doorways. Buildings treated with spray foam insulation insulate as much as 50% better than traditional insulation products.
My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)
R-value is the term given to thermal resistance to heat flow. The higher the R-value of an insulation product, the more effective the insulation properties. Spray polyurethane foam comes in a range of densities and cel structure. Low density foams are referred to as Open Cel SPF while higher density foams are referred to as Closed Cel foam. 1.8-2 pound polyurethane foam has the highest R-value of readily available spray foam insulation used in homes and buildings.[4] https://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be

I live in Baton Rouge LA with a very old and drafty house. There is no blockages in the walls between the crawl space and attic. Lots of critters just come on in. I would like to used closed cell sprayed under house to warm up floors and block moisture. I would like to spray closed cell into attic, but am afraid of enclosing attic due to moisture build-up. Can I spray closed cell against the attic floor in same way as installing bats, thus leaving my venting the same as it always has been. Other ideas? Thanks.
Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close http://www.youtube.com/v/ggLAUsiuI_o&feature=youtu.be
The drawback to spray foam insulation is it's been known to cause certain health issues such irritation of the eye and the gastrointestinal and respiratory tracts. Direct contact can cause inflammation to the skin, and some individuals have been known to break out in a rash on the arms, chest and neck area. Spray foam insulation has also been linked to a few cases of hypersensitivity pneumonitis. This condition can cause:
Ames® Roof Coatings are premium elastomeric coatings that seal out moisture, renew old surfaces and even save energy. We have products specifically formulated for all types of roofs including; Wood, Tar, Metal, Rolled Roofing, EPDM Rubber, Foam and many other surfaces. Ames’ coatings form a waterproof seal to preserve and protect your roof. Our white roof coatings reflect sunlight, substantially reducing roof temperatures. Ames® products are environmentally friendly, waterbase, non-toxic, VOC-free and water cleanup.
In general, cantilevered steel beams are a nightmare. If part of the steel beam is in contact with exterior temperatures, then it's best if the interior portion of the steel beam is covered on all sides with insulation. This is generally impossible (because the interior portion of the cantilevered beam generally supports a load, meaning that you can't wrap the steel beam in insulation on all sides).
Fill and seal expanding foam sealant is urethane Fill and seal expanding foam sealant is urethane foam designed to fill large areas quickly and permanently. Uses include filling holes cracks or gaps that require a complete airtight and waterproof seal but are too large to be filled with ordinary caulk. The foam expands approximately 3 times its original ...  More + Product Details Close 

Spray Foam Basement Walls Cost


It also has a great waterproofing ability that can shield the roof’s membrane from water and moisture damage. You can also count on the liquid roof coating for its outstanding performance for a wide range of applications and uses. This product can be used at tears and seams as well as in sealing air conditioners and venting systems and anywhere else where rubberized coating is needed.

Spray Foam Insulation


Yes, a new roof should be coated if the building owner wants to add a highly reflective roof coating to reduce energy costs. The buyer should be aware of any warranties provided for a new roof that may violate that warranty during the period it is in force via the use of a roof coating. This will extend the roof’s service life. A reflective roof coating will reduce the heat load on the roofing assembly.
The Canadian National Building Code references the CAN/ULC S705.2 National Application Standard which must be followed during all installations of 2lb medium density closed cell polyurethane foam. Every installer of CAN/ULC-S705.1 compliant medium density, spray applied foam must be licensed in order to spray foam and hold valid photo ID issued by their Quality Assurance Program (QAP) provider showing their license is in good standing.
Liquid Rubber is generally fine when applied in one coat at a 20 mil film (42 sq ft per gallon) thickness and will still withstand extremes. That is the beauty of the EPDM polymer. A second coat would provide insurance where exposures are likely to be very extreme. Radical extremes in temperature where constant surface temperatures reach 250°F or above or -20°F or below. Warning, though, if the second coat is applied at the wrong time, it may create cracking, fissures or bubbling. The second coat should be applied either when the first coat is still tacky or when that first coat has had a chance to fully cure (up to 3 months.) https://youtube.com/v/ggLAUsiuI_o?version=3
Spray foam insulation helps lower utility costs because it blocks heat and cold from the outdoors. Recent studies by the U.S. Department of Energy state that around 40 percent of all energy is lost through poor insulation. Spray foam insulation is able to insulate homes at least 50 percent more than traditional insulation products. Spray foam insulation can also provide protection against moisture, which otherwise leads to the unwanted development of mold and mildew. And it can also be used for noise reduction as well. In fact, spray foam is good for homes and buildings in which outdoor noise can be a distraction.
Although spray foam insulation has been in use since the 1940s, primarily for aircraft, for the past 30 years, continual product innovation has seen the increased adoption of spray foam insulation in residential and commercial construction. The rapid growth of sprayed foam insulation in building construction, thanks in part to its immediate and long-term benefits, has allowed the insulation material to sit confidently alongside traditional insulation types in providing thermal comfort for building occupants.
EPDM (Liquid Roof), (Liquid Rubber) Ethylene Propylene Diene Monomer. Liquid Rubber is available in White, Black Or Grey. The RV product Liquid Roof is available only in white. However, you can customize the color by adding no more than three ounces per gallon of an universal colorant (Glycol Colorant for light colors and for medium to heavy colors use a solvent based colorant available at most paint stores). If the desired color is still not achieved you may add up to ONE more additional ounce of colorant. Once the colorant is added and color achieved then you add catalyst and mix and you are ready! The Liquid Roof coating is specifically designed for RVs and trailers and mobile homes; items that are in motion. Liquid Rubber, the commercial product, is available in white or black. Custom colors are available for orders over 100 gallons. Approved Uses for Liquid EPDM Rubber.
It also has a great waterproofing ability that can shield the roof’s membrane from water and moisture damage. You can also count on the liquid roof coating for its outstanding performance for a wide range of applications and uses. This product can be used at tears and seams as well as in sealing air conditioners and venting systems and anywhere else where rubberized coating is needed.

Spray Foam Garage Door


This coating is also efficient with a coverage area reaching between 42 and 46 feet. And regardless of the weather, you can apply and use it in your roof to achieve the protection for it you need. Just as what you can read in RV rubber roof coating reviews, this product can work in all temperatures. Regardless it is hot or cold outside, you can easily apply and ensure of its adhesion on your recreational vehicle roof.
SPF insulation applied by professionals is usually described as either a high- or low-pressure foam and is available as either open- or closed-cell. Each type has advantages and disadvantages depending on the application requirements. The comparison chart below can be helpful in explaining or understanding which type of SPF insulation is best suited to a specific application.
Solvent-based polyurethane coatings have excellent adhesion and when used as a base coat over asphalt, EPDM, TPO or PVC, it eliminates the need for a primer. The resulting savings on labor and material more than offsets the higher cost of the product. When top coated with silicone, it gives you the best of both worlds. It's also an excellent gutter and RV coating. https://m.youtube.com/v/ggLAUsiuI_o
Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close
However, coating asphalt shingles and built-up composition roofs requires more caution. The National Roofing Contractors Association’s (NRCA) director of technical services has stated "The roofing industry is aware of a number of issues that could have negative consequences for field application of coatings over asphalt shingle roof systems. Anyone considering this type of application should be aware of the concerns so they can weigh them against the benefits claimed in coating product promotional materials."[2]
The problem was that the installer was doing his first spray foam job ever, and the thickness of the insulation varied from zero (visible roof deck) to about 9". Unfortunately, good average thickness doesn't cut it. The coverage needs to be uniform because a lot of heat will go through the under-insulated areas. (See my article on flat or lumpy insulation performance.) http://youtube.com/watch?feature=player_embedded&v=ggLAUsiuI_o

c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

Allison--would be very interested in your take on the GHG issues of foams, which have received lots of smart commentary recently. To highlight a few: architect Jesse Thompson's comments on Tom's Good vs Bad post on Energy Circle, the very thorough piece by Alex Wilson on Green Building Advisor and Michael Anschel's cautionary diatribe on Remodeling. 
Product innovation over the years has seen the introduction of several different types of spray foam insulation. Primarily in residential and commercial construction, open-cell and closed-cell spray foam is used while high-density spray insulation is used as roofing foam in commercial or industrial construction. Open-cell sprayed-in foam insulation, a soft low-density material, is typically used for interior applications such as wall cavities, underside of roof decks, attics, basement walls and crawlspaces. The open cell structure of low density foamed insulation allows for moisture permeability to help contribute to moisture management and bi-directional drying of the wall assembly. http://www.youtube.com/watch?v=ggLAUsiuI_o&app=desktop

A. You can use closed-cell spray foam that way if you want, although you should realize that the spray foam will prevent the roof sheathing from drying inward. This approach should only be used if the roof sheathing is bone dry, because it will never dry when sandwiched in this manner. Most building scientists would prefer to see fiberglass rather than closed-cell spray foam under the roof sheathing in this type of assembly.

If you’re looking for an effective and efficient Elastomeric Roof Coating, you might want to consider the Kool Seal roof coating. This product comes in a 115 fl oz container and is white in color. It is easy to apply and use that it can stick well even in the harshest weather conditions. This product offers maximum clinging to the RV roof despite the temperature. You can also rely on its effectiveness no matter the type of weather. https://www.youtube.com/v/ggLAUsiuI_o


While coatings may potentially stop minor leaks, the roof should be properly repaired and dried prior to coating application. Coatings may be able to seal pinhole leaks, which are leaks not visible to the naked eye. If the roof is leaking, the roof leak will need to be identified and repaired prior to any recoating; do not expect the coating to find and seal the leaks.
Whether you’re sending something fragile in the mail or keeping valuables safe during a move, secure packing is everything. To protect a delicate item, simply fill a spare shopping bag half-full with spray insulation foam and place in the bottom of a box, pressing the item gently into the bag as it hardens to cushion the item. Repeat for the top and you have a DIY custom packaging solution that can handle the rigors of delivery.
Ames® elastomeric waterproof roof coatings are premium coatings that seal out moisture, renew old surfaces and even save energy. We have products specifically formulated for all types of roofs including; Wood, Tar, Metal, Rolled Roofing, EPDM Rubber, Foam and many other surfaces. From flat roof coating to plywood roof coating, Ames’ liquid rubber roof paint coatings form a waterproof seal to preserve and protect your roof. Our white roof coatings reflect sunlight, substantially reducing roof temperatures and helping you save on cooling costs. Ames® products are environmentally friendly, water-based, non-toxic, VOC-free and can be cleaned with water. If you’re looking for how to seal a flat roof, pitched rolled roof, or just about any other kind, our elastomeric waterproof roof coatings can help you get the job done. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share

Spray foam is a very specialized packing material, often required for use in shipping valuable fragile items. Engineered packaging principles are designed to protect sculptures, vases, large fossils, lamp bases, busts, computers, furniture, chandeliers and other objects of unusual shape. By virtue of the liquid foam expanding by up to 30-60 times the volume of its liquid state, it efficiently protects almost any size, form and weight.

Stop making the same repairs using less reliable products that are not EPDM based, are not UV and ozone resistant, and do not have flexibility built into the material (causing them to crack). EPDM rubber will expand and contract with any surface as seasons change, and will not crack as a result of temperature changes. Other products will begin to bubble and crack in less than two years.

Carefully examine the roof membrane (surface material) for cracks, tears, blisters, evidence of ponding, exposed foam, and open seams. If already coated, evaluate the condition of the coating. Pay particular attention to areas around roof penetrations (vents, skylights, pipes, etc), ponding areas, cracks in parapet walls, and the attachment of roof membranes to parapet walls. Roofs should be in good condition to warrant coating.
Thoroughly clean the roof surface. Roofs collect oils from asphalt, chimneys, and cars plus lots of dirt and dust. Coatings don’t stick well to any of these. We recommend cleaning with an inexpensive solution of TSP or TSP Substitute in a bucket of water (follow label instructions). Use a broom to scrub ponding areas and areas of peeling coatings. Work a section at a time and hose off the dirty water. Sweep away puddles to promote drying. Do not allow wash water to dry on walls, furniture, windows, and visible surfaces. 
After researching this, Im curious about a method called poor mans sprayfoam where foamboard is cut to size between studs and sprayfoamed around the perimeter. Aside from the labour doing the job yourself, the cost seems comparable, is one better than the other? What about the quality of the canned sprayfoam around the perimeter? When i see sprayfoam done, it is never a full depth of the studs, so you would get 2.5-3 inches in a 3.5" (2x4) wall. Any thoughts? 
Liquid EPDM, applied over generally sound single-ply EPDM can extend the life of the single-ply EPDM an additional 20 years. Save thousands of dollars on normal roof installations. Fix roof leaks while sealing and protecting surfaces. It’s a one-coat application that works great on existing EPDM rubber roofs. No primer or top coat is needed a truly easy application! It cures only above 55°. Great for roof leaks repair, commercial and residential roof leaks repair, industrial applications, pitch and non-pitch roof repair, trailer leaks repair, camper leaks repair, RV roof leaks repair, houseboats, pond liners, basement waterproofing, roof seal leaks, shingles, gutters, steel roofs, air-conditioner enclosures, cooling towers, galvanized steel/metal roofs, unit-heater flues, concrete pipes and vessels, smoke stacks and chimneys, fiberglass, and non-porous masonry surfaces and vessels. Liquid Roof is great for roof repairs. It stops leaks ponds and fountains with Pond Pro 2000, which is specifically formulated to be safe for fish and plant life. Compare the total cost of your project. Now look at what you save in labor by doing the project yourself! Liquid Roof and Liquid Rubber are the only liquid EPDM products on the market.

How Much To Spray Foam Basement

×