Note: The practice of foam insulating the attic has raised eyebrows in the building industry because "standard" roofing techniques call for the attic to be ventilated; however, in a vented attic situation it will become approximately 130 degrees in the summer. There's no reason for an air-conditioning and vent-ductwork to have to work in that type of severe conditions. By applying Icynene right on the underside of the roof deck, the severe temperatures no longer exist in the attic. In short, the attic is now a "conditioned" space of the house that is just as comfortable as any other room in the home. This is called a "Compact Roof", which means you can frame right up against it. The one drawback of using expanded foam on the inside of the roof is that this will cause the temperature of the shingles to rise, but how much is not yet known. And how much damage a rise in temperatures could cause is debatable.


The roof must be thoroughly cleaned, and allowed to dry thoroughly. This is a critical step to ensure a successful coating application. Be careful not to damage the lap seams. Care should be taken when pressure washing not to disturb the integrity of the underlying roof membrane particularly where there are adhered seams. Refer to the specific coating manufacturer you are using for their specific requirements for roof preparation.
Part of that guidance will be explaining that interior, two component foam is applied with the professional using specific personal protective equipment (high-pressure foam is installed while using a respirator, for example). It is encouraged that professionals explain clearly to customers that this equipment, coupled with certain work and engineering practices, including ventilation, is used to minimize exposures to the chemicals used to make SPF during the job.
Note:  A board foot is defined as a 12" x 12" square at 1" thick. Actual output can be affected by a number of factors including temperature and humidity. The theoretical yield has become an industry standard for identifying certain sizes of two component kits. Theoretical yield calculations are performed in perfect laboratory conditions, without taking into account the loss of blowing agent or the variations in application methods and types. 

Loctite TITE FOAM Window and Door is a Loctite TITE FOAM Window and Door is a new generation of polyurethane-based insulating foam sealant that expands to fill seal and insulate around window and door jambs. Loctite TITE FOAM is a minimal-expanding foam based on purified and concentrated ingredients that provides four times more density versus conventional window and ...  More + Product Details Close

Check with the coating manufacturer who may be able to suggest applicators who have used their products and have familiarity with the application. Another option would be to interview contractors and ask specific questions about their proven ability to install roof coatings. Contractors affiliated with the National Roofing Contractors Association (NRCA) or local roofing contractor trade associations typically are more knowledgeable. Consult those groups’ websites for contractors.
Ames® elastomeric waterproof roof coatings are premium coatings that seal out moisture, renew old surfaces and even save energy. We have products specifically formulated for all types of roofs including; Wood, Tar, Metal, Rolled Roofing, EPDM Rubber, Foam and many other surfaces. From flat roof coating to plywood roof coating, Ames’ liquid rubber roof paint coatings form a waterproof seal to preserve and protect your roof. Our white roof coatings reflect sunlight, substantially reducing roof temperatures and helping you save on cooling costs. Ames® products are environmentally friendly, water-based, non-toxic, VOC-free and can be cleaned with water. If you’re looking for how to seal a flat roof, pitched rolled roof, or just about any other kind, our elastomeric waterproof roof coatings can help you get the job done. https://www.youtube.com/attribution_link?a=ggLAUsiuI_o&u=watch?v=XXXXXX&feature=share

We are turning our roof into an unvented roof assembly by raising the roof and blowing in SPF. We are planning to leave the existing vapor barrier down but remove the fiberglass batting and then adding 6" of SPF in all the cavities, to completely seal and insulate the house. Should we have any concerns about doing it "upside down" and not spraying the foam directly to the underside/sheathing of the roof?
“It’s been scientifically proven that the temp of the shingles rises only a couple of degrees when there is an unvented attic compared to a vented attic,” said Garry Barlow, estimator at RetroFoam of Michigan. “If we lived in a southern state it has been proven that the longevity of the shingle did diminish by only one year. In the northern states there was no difference in the life span of the shingles.”

Yes, a new roof should be coated if the building owner wants to add a highly reflective roof coating to reduce energy costs. The buyer should be aware of any warranties provided for a new roof that may violate that warranty during the period it is in force via the use of a roof coating. This will extend the roof’s service life. A reflective roof coating will reduce the heat load on the roofing assembly.


Roof coatings are easy to install. Smaller roofs in good, serviceable condition can be a weekend do-it-yourself (DIY) project. Larger roofs with leaks and ponding water issues should be coated by a qualified professional. Additional roof coating products, such as foam or coatings designed for seams, may be required underneath the main coating layers. Supplement coating products are used to reinforce damaged or leak-prone problem areas.[3]
Product innovation over the years has seen the introduction of several different types of spray foam insulation. Primarily in residential and commercial construction, open-cell and closed-cell spray foam is used while high-density spray insulation is used as roofing foam in commercial or industrial construction. Open-cell sprayed-in foam insulation, a soft low-density material, is typically used for interior applications such as wall cavities, underside of roof decks, attics, basement walls and crawlspaces. The open cell structure of low density foamed insulation allows for moisture permeability to help contribute to moisture management and bi-directional drying of the wall assembly.
Spray foam insulation, like other insulation, saves on energy costs and lowers utility bills. Studies by the US Department of Energy show that 40% of a home's energy is lost as the result of air infiltration through walls, windows and doorways. Buildings treated with spray foam insulation insulate as much as 50% better than traditional insulation products.
I am building a house in Central Texas (Caldwell). Several builders are cautious about using foam insulation and/or a closed attic. I would like to use both. Here in Texas, heat and humidity (except for the past few years of drought) are a continuing problem. Which type of foam would be the best to use in our home, where should the vapor barrier be or should be use one at all, if we are using fans in the exterior walls to supply fresh air to the house, do we need a vented attic or will it cause more problems than it solve? I have printed out your article and the blogs to give to my contractors and architect, but I would really appreciate your comments on the products being used in my part of the US.  https://www.youtube.com/v/ggLAUsiuI_o&feature=share
c) Make sure that the over expanded access is properly removed from the walls. We had a junior cutter taking too much off by bending his saw into the cavity. Look closely at the inside wall corners, and ceiling/wall corners to make sure that the foam is properly removed flush with the studs. If it has not been cut back flush it may lead to uneven drywall finishes .

Henry 587 Dura-Brite White Elastomeric Roof Coating is Henry 587 Dura-Brite White Elastomeric Roof Coating is a premium high solids formula offering better weather protection solar reflectivity and longevity than economy grade reflective roof coatings. Cured coating forms a permeable membrane which prevents liquid infiltration but allows moisture vapor to vent or breathe out of underlying substrate. Recommended ...  More + Product Details Close

Spray Foam Contractors


My other question was gonna be this. We ripped all the drywall out after Hurricane Harvey and we found some latent termite damage from some time back. One of the common studs in one corner is pretty well eaten to shreds. I was gonna brace it but then I read about more modern framing practices and I read how each stud is a thermal bridge. So now I'm thinking that I won't bother with it because the house hasn't fallen down and the foam might help a little. Unless you say to brace the stud. Then I'll do it, Martin! :)

Roof Coating Colorado

×